Specification of Solar Cable
Construction Details & Materials Solar Cable
- Conductor : Flexible of annealed tinned copper wires class 5, complied with IEC 60228.
- Separator Tape
(if necessary) : It is permitted to use a separating tape between the conductor and the
insulation.
- Insulation : Extruded of Black 125 o
C Halogen Free Cross linked Polyolefin
The average thickness of the insulation shall be not less than nominal
value given in the attached table and the minimum thickness at any point
shall be not fall bellow 90% of the nominal value by more than 0.1 mm.
- Outer Sheath : Extruded of Black 125 o
C Halogen Free Cross linked Polyolefin
The average thickness of the outer sheath shall be not less than
the nominal value given in the attached table and the minimum thickness
at any point shall be not fall below 80% of the nominal value
by more than 0.2 mm.
- Cable Identification : One lines of a distinctive marking shall be
performed continuously on a suitable place
of the surface of the outer sheath by embossing
or printing
Solar Cable